Controllers

 

Time Percentage Controller   Bulb & Capillary Controller
 

Specifications:

•  120 or 240 VAC

•  15 amps

•  Portable, plug and play design

•  6' power cord with 2 pole 3 wire plug and receptacle

•  Designed for indoor use

 

Specifications:

• 120 or 240 VAC

• 15 amp

• Portable, plug & play design

• Copper bulb & capillary, 4' long

• 6' power cord with 2 pole 3 wire plug and receptacle

•  Designed for indoor use

Volts
Amps
Range
120
15
5-100 %
240
15
5-100 %

This controller varies the proportion (length) of time the heater is in the "on" or "off" heating mode.  the heating application will deteremine the actual percentage setpoint required.  The controller does not use a temperature sensor and therefore satisfactory operation requires occasional supervision under changing load conditions.

 
Volts
Amps
Range
120
15
60° - 250° F
120
15
150° - 550° F
240
15
60° - 250° F
240
15
150° - 550° F

Bulb Dimensions 3/8" diameter x 4" long

 

Thermostat   Thermostat
 

Specifications:

•  25 amps up to 277 VAC (UL)

  25 amps up to 240 VAC (CSA)

  Surface mount

  4' power leads

  Single Pole Double Throw

 

Specifications:

•  25 amps up to 277 VAC (UL)

  25 amps up to 240 VAC (CSA)

  Surface mount

  4' power leads

  Single Pole Double Throw

  1/2" NPT flexible conduit fitting

Volts
Amps
On °F
Off °F
up to 277
25
35
50
up to 277
25
45
60
up to 277
25
60
75
up to 277
25
90
105
up to 277
25
185
200
 
Volts
Amps
On °F
Off °F
up to 277
25
35
50
up to 277
25
45
60
up to 277
25
60
75
up to 277
25
90
105
up to 277
25
185
200

 

Thermocouple Controller   Bulb and Capillary - Outdoor Use
 

Specifications:

•  120 or 240 VAC

•  15 amps

•  Temperature Ranges 0-175°, 0-500°, or 0-999°F

•  Plug-in operation

•  Type K thermoucouple

•  Proportional controlling

•  8' power cord 2 and 4-pin plug assembly

 

Specifications:

•  Rated 22 Amps up to 277 VAC

•  Differential 6° F

•  Enclosure rates NEMA 3R, for outdoor use

•  Tinned copper bulb and capillary, 10' long

•  Single Pole Double Throw contacts

•  Three different temperature ranges: 0-150°F,

    100-250°F, or 200-350°F

The Thermocouple Controller is designed for indoor, general purpose use, to control the temperature of small tanks, drums, pipes, or other applicatins requiring automatic control.  The low temperature range of the controller makes it ideal for use with plastic drums, tanks, or pipes.
 
This controller has an oil filled bulb and capillary and is used where weatherproof enclosures are necessary.  It is designed to maintain the required temperatures in heat tracing systems, freeze protection systems, process systems, and moisture protection systems.

 

Hazardous Area Bulb and Capillary  

Approvals:

UL Hazardous Locations

  Class 1, Division 1 & 2, Groups B, C, & D

  Class 2, Division 2, Groups E, F, & G

  Class 3

CSA

  Class 1, Division 1 & 2, Groups C & D

  Class 2, Division 2, Groups E, F, & G

  Class 3

Specifications:

•  Rated 22 Amps up to 480 VAC

•  304 SS Bulb and Capillary, 10' long

•  Single Pole Double Throw contacts

•  Enclosure rated NEMA 7 & 9

•  Repeatablility 1% of range

The Hazardous Area Bulb and Capillary controllers are oil filled bulb and capillary temperature controllers used for controlling individual circuits in environments requiring explosion enclosures.  These controllers are designed to maintain the required temperature in heat tracing, freeze protectin and process maintenance applications

Ambient Sensing

Volts
Amps
Range
Bulb Diameter
Bulb Length
up to 480
22
15-140° F
9/16"
2 11/16"

Single Set Point Control

Volts
Amps
Range
Bulb Diameter
Bulb Length
up to 480
22
25-325° F
1/4"
10 1/4"
up to 480
22
300-650° F
1/4"
12 1/2"

Dual Set Point Control

Volts
Amps
Range
Bulb Diameter
Bulb Length
up to 480
22
25-325° F
1/4"
10 1/4"
up to 480
22
300-650° F
1/4"
12 1/2"

The Dual Controller has two independent set-point dials and two independent SPDT contracts allowing two

different temperature set points.

 

Email for product information / pricing to:  protherm@comcast.net